Skip to content
  • Home
  • Product Categories
    • Gastroenterology
      • Cystostome
      • Percutaneous Endoscopic Gastrostomy (PEG) Kits
      • Endoscopy Accessories
      • Hemostasis
      • Polypectomy Snares
      • Bougie Dilators
      • Dilation Balloons
      • Endoscopic Biopsy Forceps
      • Stents
      • Endoscopic Retrograde Cholangiopancreatography (ERCP)
    • Cardiothoracic Surgery
    • Crtical Care & Anaesthesia
    • Obstetrics & Child Care
    • ENT
    • Neurosurgery
    • Absorbable Hemostat
    • Urology
    • General Surgery
    • Sutures
    • Biopsy Needles
    • Catheters
    • Endocavity Needle Guides
    • Specialised Wound Care
  • Photo Gallery
  • About
  • Contact Us
  • Home
  • Product Categories
    • Gastroenterology
      • Cystostome
      • Percutaneous Endoscopic Gastrostomy (PEG) Kits
      • Endoscopy Accessories
      • Hemostasis
      • Polypectomy Snares
      • Bougie Dilators
      • Dilation Balloons
      • Endoscopic Biopsy Forceps
      • Stents
      • Endoscopic Retrograde Cholangiopancreatography (ERCP)
    • Cardiothoracic Surgery
    • Crtical Care & Anaesthesia
    • Obstetrics & Child Care
    • ENT
    • Neurosurgery
    • Absorbable Hemostat
    • Urology
    • General Surgery
    • Sutures
    • Biopsy Needles
    • Catheters
    • Endocavity Needle Guides
    • Specialised Wound Care
  • Photo Gallery
  • About
  • Contact Us
Prota Limited
  • +254 791 150150 / +254 791 250250
  • info@protalimited.co.ke
  • Bayswater Court, Suite 4, Ngong Rd. Nairobi

Stents

  • Home
  • Product Categories
  • Gastroenterology
  • Stents
Esophageal Self-Expandable Metal Stent
Duodenum Self-Expandable Metal Stent
Biliary Self-Expandable Metal Stent
Pseudocyst Self-Expandable Metal Stent
Colon & Rectum Self-Expandable Metal Stent
Plastic Bile Duct Stents
Esophageal Self-Expandable Metal Stent

OESOPHAGUS STENTS (GEN-I)

Ösophagus-Stents

A comprehensive selection of self-expanding stents for bypassing oesophageal
stenoses. The stents are characterised by very high flexibility and are available with and without covering. The working diameter of the stent is 20. 24 or 28 mm while lengths vary of between 60 and 140 mm. Therefore, the optimum solution is always at hand for every indication.

SpecificCharacteristics

• Self-expanding
• Nitinol mesh with atraumatic ends
• Excellent positional stability
• High radial force
• Resistant and elastic covering
• Fully covered stents available
• Parylene coated
• High radiopacity
• Extraction threads for removal and repositioning
• Guide wire-compatible up to 0.035 inches

Practicable

The stent adapts to the oesophageal wall in the best
possible manner thanks to its atraumatic shape and high
radial force. Furthermore, the stent possesses excellent
radiopacity and can be positioned with good visibility and
precision at significant points with the aid of the additional
X-ray markings.

Positionally Stable Design

Oeso_Stent_stentdesign

The oesophagus stent is extremely positionally stable.
Its self-expanding Nitinol wire adapts itself perfectly to
the patient’s anatomy and the atraumatic ends ensure a
maximum hold.

Diameters up to 28mm

Oeso_Stent_Durchmesser

Three different diameters:
20. 24 or 28 mm in the central section. The stent end is
6 mm wider in each case.

Five Standard Lengths

Oeso_Stent_Längen

Short stents
measuring 60 and 80 mm, medium lengths of 100 and
120 mm and long versions of 140 mm.

Radiopaque Markers For Secure Insertion Of Stents

Oeso_Stent_10Xray

All of our esophagus stents are equipped with up to 10 radiopaque markers. They are clearly visible under radiological control and thus enable a secure and precise stent release.

With And Without Covering

Depending on the model, the stents have a protective covering. Choose between a complete covering from one stent end to the other, a partial covering in which the ends remain free and a cover-free stent.

 

Point Of No Return

A mark on the delivery system shows the “point of no return” at stent placement.

Introducer For Precise Release

All stents are preloaded on the easy-to-manipulate introducer, which allows rapid and precise stent release. The system also allows you to bring the stent into the desired position even when in the oral cavity during release.

SPECIFICATIONS

REF

Ø centre mm

Ø end mm

Length mm

Covering mm

STENTS WITHOUT COVERING

 

ST01-101.20.080

20

26

80

Without

ST01-101.20.100

20

26

100

Without

ST01-101.20.120

20

26

120

Without

ST01-101.20.140

20

26

140

Without

ST01-101.24.080

24

30

80

Without

ST01-101.24.100

24

30

100

Without

ST01-101.24.120

24

30

120

Without

ST01-101.24.140

24

30

140

Without

STENTS WITH PARTIAL COVERING

 

ST01-102.20.060

20

26

60

30

ST01-102.20.080

20

26

80

50

ST01-102.20.100

20

26

100

70

ST01-102.20.120

20

26

120

90

ST01-102.20.140

20

26

140

110

ST01-102.24.080

24

30

80

50

ST01-102.24.100

24

30

100

70

ST01-102.24.120

24

30

120

90

ST01-102.24.140

24

30

140

110

STENTS WITH END-TO-END COVERING

 

ST01-103.20.060

20

26

60

60

ST01-103.20.080

20

26

80

80

ST01-103.20.100

20

26

100

100

ST01-103.20.120

20

26

120

120

ST01-103.20.140

20

26

140

140

ST01-103.24.060

24

30

60

60

ST01-103.24.080

24

30

80

80

ST01-103.24.100

24

30

100

100

ST01-103.24.120

24

30

120

120

ST01-103.24.140

24

30

140

140

ST01-103.28.100

28

34

100

100

ST01-103.28.120

28

34

120

120

INTRODUCER SYSTEM

Ø mm/fr.

Length mm

Guide wire

RM*1

IC*2

Lock*3

8/24

700

0.035 inch

2

Yes

Yes

 

CARDIA-UMBRELLA-STENT

Cardia-Umbrella-Stent-titel

A specially designed stent perfectly tailored to the challenging anatomical diagnosis of the cardia. Its unique design gives the stent extremely high positional stability and prevents its migration in both the gastric and oral directions. Since the lower oesophageal sphincter lies between the bulbous section and the distal end of the stent we have implemented a special feature which is an “opened umbrella” type shape to facilitate this anatomical challenge. Furthermore, the stent does not protrude into the stomach as a result of this umbrella-shaped design, ending directly behind the oesophageal gastric junction. The risk of pressure necrosis is thus significantly reduced and any potential patient discomfort is decreased.

Specific Characteristics

  • Unique umbrella design
  • Self-expanding
  • Nitinol mesh with atraumatic ends
  • Excellent positional stability
  • High radial force
  • Resistant and elastic covering
  • Fully covered stents available
  • High radiopacity
  • Extraction threads for removal and repositioning
  • Guide wire-compatible up to 0.035 inches

UMBRELLA-VALVE

Together with the high radial force, the spherical proximal end and the complete covering, the innovative umbrella design guarantees ideal hold in the area of the cardia. Radiopaque markers in prominent positions ease the placement of the stent under radiological view.

REF

Ø centre mm

Ø end prox./bulge/end

dist. mm

Length mm

Covering mm

End design

Proximal

Distal

 

STENTS WITH PARTIAL COVERING

ST01-108.24.100

24

30/30/50

100

85

Spherical

Umbrella

ST01-108.24.120

24

30/30/50

120

105

Spherical

Umbrella

STENTS WITH END-TO-END COVERING

ST01-109.24.100

24

30/30/50

100

100

Spherical

Umbrella

ST01-109.24.120

24

30/30/50

120

120

Spherical

Umbrella

Ø mm/fr.

Length mm

Guide wire

RM*1

IC*2

Lock*3

 

INTRODUCER SYSTEM

 

8.5/25

700

0.035 inch

2

Yes

Yes

 

Duodenum Self-Expandable Metal Stent

DUODENUM STENTS

Duodenum-Stent-titel

The self-expanding Nitinol stents are used to bypass stenoses in the duodenum. Their spherical ends adapt perfectly to the anatomy of the duodenum, thereby guaranteeing maximum positional stability. Stents with and without covering are available depending on the indication. The duodenual stent is preloaded on a TTS introducer (through-the-scope) as standard. Insertion is therefore carried out through the working channel of the endoscope and release of the stent is observed endoscopically. X-ray markings on the introducer and on the stent itself ensure optimum radiological visualisation.

Specific Characteristics

Oeso_Stent_ExtraktionsfadenOeso_Stent_Xray

• Spherical ends
• Self-expanding
• Nitinol mesh with atraumatic ends
• Release under endoscopic observation
• Excellent positional stability
• Resistant and elastic covering
• High radiopacity
• Extraction threads for removal and repositioning
• Guide wire-compatible up to 0.035 inches

DUODENUM-längen

With a diameter of 20 mm and different lengths of 60.
80. 100 or 120 mm, the range of duodenual stents always
provides the right size for your patient.

SPECIFICATIONS

REF

Ø centre mm

Ø end mm

Length mm

Covering mm

STENTS WITHOUT COVERING

ST02-101.20.060

20

26

60

Without

ST02-101.20.080

20

26

80

Without

ST02-101.20.100

20

26

100

Without

ST02-101.20.120

20

26

120

Without

STENTS WITH PARTIAL COVERING

ST02-102.20.060

20

26

60

40

ST02-102.20.080

20

26

80

60

ST02-102.20.100

20

26

100

80

Ø mm/fr.

Length mm

Guide wire

RM*1

IC*2

Lock*3

INTRODUCER SYSTEM

3.3/10

1800

0.035 inch

2

Yes

Yes

Biliary Self-Expandable Metal Stent

BILIARY DUCT STENTS

Gallengang Kurzdraht

The high expansion force of the Nitinol wire mesh accounts for an excellent positional stability. The resistant cover prevents the stent from growing into the tissue. The product range comprises two stent lines and offers a first-class solution that suits all requirements: the classic line and the platinum line. The comprehensive platinum line is especially distinguished by its extraordinary high radiopacity.

Specific Characteristics

Gallengang_Xray_tech

• Self-expanding
• Available for TTS and PTCD
• Classic- and Platinum-Line
• Nitinol wire mesh with atraumatic ends
• Release under visual endoscopic control
• Enormous position stability
• Resistant and elastic cover
• High radiopacity
• Guiding wire passable to a maximum of 0.035 inches

The Classic-Line is perfectly suited for all standard interventions. With two different approaches consisting of TTS and PTCD, it perfectly meets every requirement. These stents are made of highly flexible Nitinol wire mesh. Ten additional radiopaque markers account for the good visibility of our Classic-Line stents under fluoroscopy. Our product range comprises uncovered and partially covered stents.

PTCD For Percutaneous Access

In case of therapeutic interventions into the biliary duct, it sometimes occurs that a transpapillary access cannot be accomplished. In such cases MICRO-TECH offers PTCD systems (percutaneous transhepatic cholangio drainage) as the ideal solution.

TTS Stents For Routine Interventions

We offer uncovered as well as partially covered biliary duct stents in three different lengths. All stents can be placed through the working channel of the duodenoscope over the inserted guide wire (TTS – through-the-scope).

Introducer System For An Exact Release

Additional radiopaque markers on the distal end of the introducer system and on the tip of the pusher catheter provide for additional orientation. In the endoscopic image, the tip of the pusher catheter can be unambiguously and easily distinguished from the proximal end of the stent. The permanent visual endoscopic control of the stent‘s proximal end considerably facilitates the exact release of the stent.

Ten Platinum Radiopaque Markers

In order to achieve improved visibility under X-ray control each stent bares a total of ten radiopaque markers: four markers located at each end, and two in the middle of the stent. The two radiopaque markers in the middle guarantee for the controllability of the stent‘s optimal position during deployment.

Specifications

REF

Ø centre mm

Ø end mm

Length mm

Covering mm

CLASSIC-LINE TTS

ST03-101.10.040

10

10

40

Without

ST03-101.10.060

10

10

60

Without

ST03-101.10.080

10

10

80

Without

ST03-101.10.100

10

10

100

Without

ST03-102.10.060

10

10

60

50

ST03-102.10.080

10

10

80

70

ST03-102.10.100

10

10

100

90

CLASSIC-LINE PTCD

ST03-111.10.060

10

10

60

Without

ST03-111.10.080

10

10

80

Without

ST03-112.10.060

10

10

60

50

ST03-112.10.080

10

10

80

70

PLATINUM-LINE TTS

ST03-104.10.040

10

10

40

Without

ST03-104.10.060

10

10

60

Without

ST03-104.10.080

10

10

80

Without

ST03-104.10.100

10

10

100

Without

ST03-105.10.040

10

10

40

30

ST03-105.10.060

10

10

60

50

ST03-105.10.080

10

10

80

70

ST03-105.10.100

10

10

100

90

ST03-106.10.040

10

10

40

40

ST03-106.10.060

10

10

60

60

ST03-106.10.080

10

10

80

80

PLATINUM-LINE TTS, EXTENDED ENDS, EXTRACTION THREADS PRE-PAPILLARY

ST03-126.10.040

10

10

40

30

ST03-126.10.060

10

10

60

50

ST03-126.10.080

10

10

80

70

ST03-127.10.040

10

10

40

40

ST03-127.10.060

10

10

60

60

ST03-127.10.070

10

10

70

70

ST03-127.10.080

10

10

80

80

Ø mm/fr.

Length mm

Guide wire

RM*1

IC*2

Lock*3

INTRODUCER SYSTEM

ST03-101… (TTS)

2.7/8

1800

0.035 inch

2

Yes

Yes

ST03-102 + 103… (TTS)

3.0/9

1800

0.035 inch

2

Yes

Yes

ST03-111… (PTCD)

2.7/8

500

0.035 inch

2

Yes

Yes

ST03-112… (PTCD)

2.8/8.5

500

0.035 inch

2

Yes

Yes

ST03-126… (TTS)

3.0/9

1800

0.035 inch

2

Yes

Yes

ST03-127… (TTS)

3.3/10

1800

0.035 inch

2

Yes

Yes

BILIARY-STENT (GEN-II)

Gallengan-Stent_GEN-II_Titel_DE_1

Thanks to its slim design, the system can be pushed almost frictionless through the endoscope and released easily in the bile-duct. A high flexible, specially developed Nitinol wire and the tantalum markers ensure optimal placement under X-ray vision. The range of stents are available in lengths from 40 to 100 mm as well as fully, partially and uncovered stents. Uncovered and partially covered variants are produced with a “point-of-no-return” that allows to re-insert the stent into the sheath again and make the repositioning much easier.

Specific Characteristics

Gallengang-Stent_GEN-II_detail-1Gallengang-Stent_GEN-II_detail-2

• Slimmer introducer set
• Point-of-no-return for uncovered and partially
covered stents
• Stent system does not need to be flushed
before application
• Stent with tantalum marker for good visibility
under X-ray

Specifications

REF

Ø mm

Length mm

Working channel mm

Covering

STENTS STRAIGHT

NST03-001-10.040

10

40

3.7

Without

NST03-001-10.060

10

60

3.7

Without

NST03-001-10.080

10

80

3.7

Without

NST03-001-10.100

10

100

3.7

Without

NST03-002-10.040

10

40

3.7

Partial

NST03-002-10.060

10

60

3.7

Partial

NST03-002-10.080

10

80

3.7

Partial

NST03-002-10.100

10

100

3.7

Partial

NST03-004-10.040

10

40

3.7

Complete

NST03-004-10.060

10

60

3.7

Complete

NST03-004-10.080

10

80

3.7

Complete

NST03-004-10.100

10

100

3.7

Complete

STENTS WITH EXTENDED TULIPS

NST03-111-10.040

10/13

40

3.7

Without

NST03-111-10.060

10/13

60

3.7

Without

NST03-111-10.080

10/13

80

3.7

Without

NST03-111-10.100

10/13

100

3.7

Without

NST03-112-10.040

10/13

40

3.7

Partial

NST03-112-10.060

10/13

60

3.7

Partial

NST03-112-10.080

10/13

80

3.7

Partial

NST03-112-10.100

10/13

100

3.7

Partial

NST03-114-10.040

10/13

40

3.7

Complete

NST03-114-10.060

10/13

60

3.7

Complete

NST03-114-10.080

10/13

80

3.7

Complete

NST03-114-10.100

10/13

100

3.7

Complete

Ø mm/fr.

Length mm

Guide wire

RM*1

Lock*2

INTRODUCER SYSTEM

2.5 mm/7.5 fr., 2.8 mm/8.5 fr.

1800

0.035 inch

2

Yes

SHOW-METAL-STENT

Indicated for applications in the bile duct and is suitable for both short and long wire systems. Time-consuming preparation and irrigation is no longer necessary. Made of flexible nitinol wire, the stent is designed to adapt ideally to biliary conditions. The atraumatic stent ends are characterized by their soft edges. For precise placement, there are overall 10 radiopaque markers on the stent itself and three more on the introducer set. The point-of-no-return (for uncovered and partially covered stents) allows resheathing of the stent which means it can be repositioned. The guide wire exit is located at approx. 30 cm. Our range includes stents with four different lengths of 40 to 100 mm and thus offers for each operation the ideal solution.

Specific Characteristics

SHOW-Metal-Stent_Galerie_5SHOW-Metal-Stent_Galerie_6SHOW-Metal-Stent_Galerie_1SHOW-Metal-Stent_Galerie_2

• Short and long wire compatible
• No preparation or flushing necessary
• Easy handling
• Uncovered, partially covered and fully covered
• Available in a straight form
• Automatic guide wire exit
• Point-of-no-return
• Very good visibility through tantalum markers
• Very flexible application system facilitates the
placement

PLATINUM-LINE

Platinum-Line

Under X-ray control, they are more visible than ever before, making their release even safer and precise. The secret of their extremely good visibility lies in the specially developed Nitinol wire. Now with enhanced radiopacity, these platinum stents virtually glow in X-ray images. This accounts for extremely good visibility of the stent over its entire length under fluoroscopy.

Apart from the innovative Nitinol wire, each stent of the Platinum-Line is distinguished by two additional radiopaque markers which are located in the middle of the stent. This enables pinpointing the exact position of the stent‘s center line while the stent is being released. Additional radiopaque markers on the introducer system also facilitate orientation.

PLATINUM-LINE-längen

The biliary stents are 10 mm wide throughout and differ in length according to the indication: a choice of five lengths is available, namely 40. 60. 70. 80 and 100 mm.

Specifications

REF

Ø centre mm

Ø end mm

Length mm

Covering mm

CLASSIC-LINE TTS

ST03-101.10.040

10

10

40

Without

ST03-101.10.060

10

10

60

Without

ST03-101.10.080

10

10

80

Without

ST03-101.10.100

10

10

100

Without

ST03-102.10.060

10

10

60

50

ST03-102.10.080

10

10

80

70

ST03-102.10.100

10

10

100

90

CLASSIC-LINE PTCD

ST03-111.10.060

10

10

60

Without

ST03-111.10.080

10

10

80

Without

ST03-112.10.060

10

10

60

50

ST03-112.10.080

10

10

80

70

PLATINUM-LINE TTS

ST03-104.10.040

10

10

40

Without

ST03-104.10.060

10

10

60

Without

ST03-104.10.080

10

10

80

Without

ST03-104.10.100

10

10

100

Without

ST03-105.10.040

10

10

40

30

ST03-105.10.060

10

10

60

50

ST03-105.10.080

10

10

80

70

ST03-105.10.100

10

10

100

90

ST03-106.10.040

10

10

40

40

ST03-106.10.060

10

10

60

60

ST03-106.10.080

10

10

80

80

PLATINUM-LINE TTS, EXTENDED ENDS, EXTRACTION THREADS PRE-PAPILLARY

ST03-126.10.040

10

10

40

30

ST03-126.10.060

10

10

60

50

ST03-126.10.080

10

10

80

70

ST03-127.10.040

10

10

40

40

ST03-127.10.060

10

10

60

60

ST03-127.10.070

10

10

70

70

ST03-127.10.080

10

10

80

80

Ø mm/fr.

Length mm

Guide wire

RM*1

IC*2

Lock*3

INTRODUCER SYSTEM

ST03-101… (TTS)

2.7/8

1800

0.035 inch

2

Yes

Yes

ST03-102 + 103… (TTS)

3.0/9

1800

0.035 inch

2

Yes

Yes

ST03-111… (PTCD)

2.7/8

500

0.035 inch

2

Yes

Yes

ST03-112… (PTCD)

2.8/8.5

500

0.035 inch

2

Yes

Yes

ST03-126… (TTS)

3.0/9

1800

0.035 inch

2

Yes

Yes

ST03-127… (TTS)

3.3/10

1800

0.035 inch

2

Yes

Yes

Pseudocyst Self-Expandable Metal Stent

PSEUDOCYST STENT (GEN-II)

Nitinol-Stents-Psedozysten Stent

The Pancreastic pseudocyst stent is used for reliable drainage of endoscopically removed concrement. The design of the stent with its distal umbrella and proximal tulip shapes, ensures that during an eventual migration a dislocation would only occur into the stomach and not into the cyst. The large diameter of 16 mm in the middle of the stent allows for endoscopic removal of concrement. The 10.5 French TTS (through-the-scope) insertion system is brought into position through the working channel of the endoscope with the aid of a guide wire. When the stent is released, 4 radiopaque markers at each end of the stent guarantee excellent identification on radiological images.

Specific Characteristics

• Stent with complete silicone covering
• High degree of positional stabilityl
• Atraumatic tips
• High level of radial force
• Tantalum radiomarkers
• Guide wire passage up to 0.035 inches
• TTS insertion system with 3.5 mm diameter,
1,800 mm length, two x-ray markings, rinsing
attachment and lock to secure the introducer
set during transport, storage and insertion.

Colon & Rectum Self-Expandable Metal Stent

COLONIC STENTS TTS

Kolon-Stents TTS

Whereas OTW systems can be placed over-the-wire, TTS (through-the-Scope)colonic stents can be delivered though the working channel of the colonoscope. This way, application time is reduced dramatically. Due to the visible endoscopic control during placement stent deployment takes place in an even more controlled fashion. In comparison with OTW colonic and rectal stents, TTS applications are especially flexible and better suited for the curved segments of the colon, e.g. the right and left colonic flexures.

Specific Characteristics

• Self-expanding
• Nitinol wire mesh with atraumatic ends
• Flexible and positionally stable
• 10 Radiopaque markers for enhanced visibility
under X-ray
• Extraction threads for removal and repositioning
• Guide wire passable up to 0.035 inches

KOLON-TTS_gesamt

As a standard among TTS colonic stents, you can choose from four different lengths: 60, 80, 100, and 120 mm for stents without covering. In all other versions the stent end working diameter amounts to 25 mm and to 30 mm. The introducer system for TTS colonic stents has a diameter of 10 fr. (= 3.3 mm). It therefore fits to all working channels having a diameter of at least 3.6 mm.

Specifications

REF

Ø centre mm

Ø end mm

Length mm

Covering mm

Application

End design

STENTS WITHOUT COVERING

ST04-104.25.060

25

30

60

Without

Colon

Spherical

ST04-104.25.080

25

30

80

Without

Colon

Spherical

ST04-104.25.100

25

30

100

Without

Colon

Spherical

ST04-104.25.120

25

30

120

Without

Colon

Spherical

Ø mm/fr.

Length mm

Guide wire

RM*1

IC*2

Lock*3

INTRODUCER SYSTEM

3.3/10

2300

0.035 inch

2

Yes

Yes

 

COLONIC AND RECTAL STENTS OTW

Kolon- und Rektum-Stents OTW

The OTW (over-the-wire) colonic and rectal stents of MICRO-TECH have a particularly high positional stability. In the OTW colonic stents this is achieved via a square-edged transition, situated near each end of the stent. This virtually anchors the stent inside the lumen and adapts it optimally to the anatomy and peristalsis of the colon. In contrast, rectal stents are less stimulating and hence more “ball-shaped”. This ensures the patient experiences less irritations in this sensitive area, thus decisively increasing quality of life. The partially sheathed OTW colonic and rectal stents produce very high radial forces. Therefore, they should be placed into straight segments of the colon, and not into the bent segments, such as the right and left flexure of the colon.

Specific Characteristics

KOLON-REKTUM-KugelKOLON-REKTUM-Pilz

  • Nitinol mesh with atraumatic ends
  • Anatomical design
  • Excellent positional stability
  • High radial force
  • Resistant and elastic covering
  • High radiopacity
  • Extraction threads for removal and repositioning
  • Guide wire-compatible up to 0.035 inches

Colonic and rectal stents are available in lengths of 80 mm and 100 mm. Stents for patients who have undergone anastomosis have a length of 60 mm. You can choose between non-covered, partially covered and end-to-end covered versions.

KOLON-techREKTUM-tech

Specifications

REF

Ø centre mm

Ø end mm

Length mm

Covering mm

Application

End design

STENTS WITHOUT COVERING

ST04-101.30.080

30

36

80

Without

Colon

Mushroom

ST04-101.30.100

30

36

100

Without

Colon

Mushroom

ST04-111.30.080

30

36

80

Without

Rectum

Spherical

ST04-111.30.100

30

36

100

Without

Rectum

Spherical

STENTS WITH PARTIAL COVERING

ST04-102.30.080

30

36

80

50

Colon

Mushroom

ST04-102.30.100

30

36

100

70

Colon

Mushroom

ST04-112.30.080

30

36

80

50

Rectum

Spherical

ST04-112.30.100

30

36

100

70

Rectum

Spherical

ANASTOMOSIS STENTS WITH END-TO-END COVERING

ST04-109.20.060

20

26

60

60

Colon

Spherical

ST04-109.26.060

26

32

60

60

Colon

Spherical

ST04-109.30.060

30

36

60

60

Colon

Spherical

Ø mm/fr.

Length mm

Guide wire

RM*1

IC*2

Lock*3

INTRODUCER SYSTEM

ST04-111 + 112…

8/24

700

0.035 inch

2

Yes

Yes

ST04-101 + 102 + 109…

8/24

1100

0.035 inch

2

Yes

Yes

Plastic Bile Duct Stents

Offering a comprehensive range of plastic stents for short and medium-term drainage in the bile duct. The stents are available in different shapes, lengths and diameters. Thus, the ideal stent is available for each indication. The high-quality PE-/PTFE-material of the stents ensures reliable drainage and adapts optimally to the anatomy of the patient. Flaps at the ends of the stents also ensure a secure hold with minimal migration. For rapid and safe implantation, the stents are available both individually and on pre-loaded systems.

Specific Characteristcs

• Different shapes: straight, curved, angled,
pigtail, double-pigtail
• Optimum flow rate
• Ideal adaptation to anatomy
• Safe hold, minimal migration
• Available single-packed or pre-loaded
on introduction-system
• High x-ray visibility

 

Specifications

Stent Straight

Plastik Gallengang Stent gerade

  • Shape: straight
  • 2 flaps
  • 2 side-holes
  • X-ray visible
  • Material: PE

Working length

Diameter bile duct prosthesis

7FR

8.5FR

10FR

11.5FR

 

5 cm

BPDS-31114-0705

BPDS-31114-0805

BPDS-31114-1005

BPDS-31114-1105

6 cm

BPDS-31114-0706

BPDS-31114-0806

BPDS-31114-1006

BPDS-31114-1106

7 cm

BPDS-31114-0707

BPDS-31114-0807

BPDS-31114-1007

BPDS-31114-1107

8 cm

BPDS-31114-0708

BPDS-31114-0808

BPDS-31114-1008

BPDS-31114-1108

9 cm

BPDS-31114-0709

BPDS-31114-0809

BPDS-31114-1009

BPDS-31114-1109

10 cm

BPDS-31114-0710

BPDS-31114-0810

BPDS-31114-1010

BPDS-31114-1110

11 cm

BPDS-31114-0711

BPDS-31114-0811

BPDS-31114-1011

BPDS-31114-1111

12 cm

BPDS-31114-0712

BPDS-31114-0812

BPDS-31114-1012

BPDS-31114-1112

13 cm

BPDS-31114-0713

BPDS-31114-0813

BPDS-31114-1013

BPDS-31114-1113

14 cm

BPDS-31114-0714

BPDS-31114-0814

BPDS-31114-1014

BPDS-31114-1114

15 cm

BPDS-31114-0715

BPDS-31114-0815

BPDS-31114-1015

BPDS-31114-1115

Stent Curved

Plast Gallengang Stent gebogen• Shape: 15° curved
• 2 flaps
• 2 side-holes
• X-ray visible
• Material: PE

Working length

Diameter bile duct prosthesis

7FR

8.5FR

10FR

11.5FR

 

5 cm

BPDS-32114-0705

BPDS-32114-0805

BPDS-32114-1005

BPDS-32114-1105

6 cm

BPDS-32114-0706

BPDS-32114-0806

BPDS-32114-1006

BPDS-32114-1106

7 cm

BPDS-32114-0707

BPDS-32114-0807

BPDS-32114-1007

BPDS-32114-1107

8 cm

BPDS-32114-0708

BPDS-32114-0808

BPDS-32114-1008

BPDS-32114-1108

9 cm

BPDS-32114-0709

BPDS-32114-0809

BPDS-32114-1009

BPDS-32114-1109

10 cm

BPDS-32114-0710

BPDS-32114-0810

BPDS-32114-1010

BPDS-32114-1110

11 cm

BPDS-32114-0711

BPDS-32114-0811

BPDS-32114-1011

BPDS-32114-1111

12 cm

BPDS-32114-0712

BPDS-32114-0812

BPDS-32114-1012

BPDS-32114-1112

13 cm

BPDS-32114-0713

BPDS-32114-0813

BPDS-32114-1013

BPDS-32114-1113

14 cm

BPDS-32114-0714

BPDS-32114-0814

BPDS-32114-1014

BPDS-32114-1114

15 cm

BPDS-32114-0715

BPDS-32114-0815

BPDS-32114-1015

BPDS-32114-1115

Stent Lateral Angled

Plastik Gallengang Stent gewinkelt

  • Form: 45° lateral angled
  • 2 flaps
  • 2 side-holes
  • X-ray visible
  • Material: PE

Working length

Diameter bile duct prosthesis

7FR

8.5FR

10FR

11.5FR

 

5 cm

BPDS-33114-0705

BPDS-33114-0805

BPDS-33114-1005

BPDS-33114-1105

6 cm

BPDS-33114-0706

BPDS-33114-0806

BPDS-33114-1006

BPDS-33114-1106

7 cm

BPDS-33114-0707

BPDS-33114-0807

BPDS-33114-1007

BPDS-33114-1107

8 cm

BPDS-33114-0708

BPDS-33114-0808

BPDS-33114-1008

BPDS-33114-1108

9 cm

BPDS-33114-0709

BPDS-33114-0809

BPDS-33114-1009

BPDS-33114-1109

10 cm

BPDS-33114-0710

BPDS-33114-0810

BPDS-33114-1010

BPDS-33114-1110

11 cm

BPDS-33114-0711

BPDS-33114-0811

BPDS-33114-1011

BPDS-33114-1111

12 cm

BPDS-33114-0712

BPDS-33114-0812

BPDS-33114-1012

BPDS-33114-1112

13 cm

BPDS-33114-0713

BPDS-33114-0813

BPDS-33114-1013

BPDS-33114-1113

14 cm

BPDS-33114-0714

BPDS-33114-0814

BPDS-33114-1014

BPDS-33114-1114

15 cm

BPDS-33114-0715

BPDS-33114-0815

BPDS-33114-1015

BPDS-33114-1115

Stent Central Angled

Plastik Gallengang Stent mittig gewinkelt

  • Shape: 90° central angled
  • 2 flaps
  • 2 side-holes
  • X-ray visible
  • Material: PE

Working length

Diameter bile duct prosthesis

7FR

8.5FR

10FR

11.5FR

 

5 cm

BPDS-34114-0705

BPDS-34114-0805

BPDS-34114-1005

BPDS-34114-1105

6 cm

BPDS-34114-0706

BPDS-34114-0806

BPDS-34114-1006

BPDS-34114-1106

7 cm

BPDS-34114-0707

BPDS-34114-0807

BPDS-34114-1007

BPDS-34114-1107

8 cm

BPDS-34114-0708

BPDS-34114-0808

BPDS-34114-1008

BPDS-34114-1108

9 cm

BPDS-34114-0709

BPDS-34114-0809

BPDS-34114-1009

BPDS-34114-1109

10 cm

BPDS-34114-0710

BPDS-34114-0810

BPDS-34114-1010

BPDS-34114-1110

11 cm

BPDS-34114-0711

BPDS-34114-0811

BPDS-34114-1011

BPDS-34114-1111

12 cm

BPDS-34114-0712

BPDS-34114-0812

BPDS-34114-1012

BPDS-34114-1112

13 cm

BPDS-34114-0713

BPDS-34114-0813

BPDS-34114-1013

BPDS-34114-1113

14 cm

BPDS-34114-0714

BPDS-34114-0814

BPDS-34114-1014

BPDS-34114-1114

15 cm

BPDS-34114-0715

BPDS-34114-0815

BPDS-34114-1015

BPDS-34114-1115

Pigtail Double

Plastik Gallengang Stent Pigtail doppelt

  • Shape: Pigtail
  • Double
  • 4 side-holes
  • X-ray visible
  • Material: PE

Working length

Diameter bile duct prosthesis

7FR

8.5FR

10FR

11.5FR

 

5 cm

BPDS-31993-0705

BPDS-31993-0805

BPDS-31993-1005

BPDS-31993-1105

6 cm

BPDS-31993-0706

BPDS-31993-0806

BPDS-31993-1006

BPDS-31993-1106

7 cm

BPDS-31993-0707

BPDS-31993-0807

BPDS-31993-1007

BPDS-31993-1107

8 cm

BPDS-31993-0708

BPDS-31993-0808

BPDS-31993-1008

BPDS-31993-1108

9 cm

BPDS-31993-0709

BPDS-31993-0809

BPDS-31993-1009

BPDS-31993-1109

10 cm

BPDS-31993-0710

BPDS-31993-0810

BPDS-31993-1010

BPDS-31993-1110

11 cm

BPDS-31993-0711

BPDS-31993-0811

BPDS-31993-1011

BPDS-31993-1111

12 cm

BPDS-31993-0712

BPDS-31993-0812

BPDS-31993-1012

BPDS-31993-1112

13 cm

BPDS-31993-0713

BPDS-31993-0813

BPDS-31993-1013

BPDS-31993-1113

14 cm

BPDS-31993-0714

BPDS-31993-0814

BPDS-31993-1014

BPDS-31993-1114

15 cm

BPDS-31993-0715

BPDS-31993-0815

BPDS-31993-1015

BPDS-31993-1115

Pigtail Distal

Plastik Gallengang Stent Pigtail Dist Proxi

  • Shape: Pigtail
  • Distal
  • 2 side-holes
  • X-ray visible
  • Material: PE

Working length

Diameter bile duct prosthesis

8.5FR

10FR

 

5 cm

BPDS-31196-0805

BPDS-31196-1005

6 cm

BPDS-31196-0806

BPDS-31196-1006

7 cm

BPDS-31196-0807

BPDS-31196-1007

8 cm

BPDS-31196-0808

BPDS-31196-1008

9 cm

BPDS-31196-0809

BPDS-31196-1009

10 cm

BPDS-31196-0810

BPDS-31196-1010

11 cm

BPDS-31196-0811

BPDS-31196-1011

12 cm

BPDS-31196-0812

BPDS-31196-1012

13 cm

BPDS-31196-0813

BPDS-31196-1013

14 cm

BPDS-31196-0814

BPDS-31196-1014

15 cm

BPDS-31196-0815

BPDS-31196-1015

Pigtail Proximal

Plastik Gallengang Stent Pigtail Dist Proxi

  • Shape: Pigtail
  • Proximal
  • 2 side-holes
  • X-ray visible
  • Material: PE

Working length

Diameter bile duct prosthesis

8.5FR

10FR

 

5 cm

BPDS-31916-0805

BPDS-31916-1005

6 cm

BPDS-31916-0806

BPDS-31916-1006

7 cm

BPDS-31916-0807

BPDS-31916-1007

8 cm

BPDS-31916-0808

BPDS-31916-1008

9 cm

BPDS-31916-0809

BPDS-31916-1009

10 cm

BPDS-31916-0810

BPDS-31916-1010

11 cm

BPDS-31916-0811

BPDS-31916-1011

12 cm

BPDS-31916-0812

BPDS-31916-1012

13 cm

BPDS-31916-0813

BPDS-31916-1013

14 cm

BPDS-31916-0814

BPDS-31916-1014

15 cm

BPDS-31916-0815

BPDS-31916-1015

 

Introducer-Systems Without Stent

Plastik Gallengang System oStent

  • One step introducer-system
  • X-ray visible

REF

Ø catheter

Guide catheter

Introducer length

BPDI-0740/22

7 FR

40 cm

220 cm

BPDI-0840/22

8.5 FR

40 cm

220 cm

BPDI-1040/22

10 FR

40 cm

220 cm

BPDI-1140/22

11.5 FR

40 cm

220 cm

Stent Straight

Plastik Gallengang Stent gerade

  • Shape: straight
  • 2 flaps
  • 2 side-holes
  • X-ray visible
  • Material: PE

REF

Ø catheter

Stent working/

total length

Introducer length

BPDS-31114-0805/22

8.5 FR

5 / 7 cm

220 cm

BPDS-31114-0807/22

8.5 FR

7 / 9 cm

220 cm

BPDS-31114-0809/22

8.5 FR

9 / 11 cm

220 cm

BPDS-31114-0811/22

8.5 FR

11 / 13 cm

220 cm

BPDS-31114-1005/22

10 FR

5 / 7 cm

220 cm

BPDS-31114-1007/22

10 FR

7 / 9 cm

220 cm

BPDS-31114-1009/22

10 FR

9 / 11 cm

220 cm

BPDS-31114-1011/22

10 FR

11 / 13 cm

220 cm

Stent Curved

Plastik-Gallengang_Stent gewinkelt 2

  • Shape: 15° curved
  • 2 flaps
  • 2 side-holes
  • X-ray visible
  • Material: PE

REF

Ø catheter

Stent working/

total length

Introducer length

BPDS-32114-0805/22

8.5 FR

5 / 7 cm

220 cm

BPDS-32114-0807/22

8.5 FR

7 / 9 cm

220 cm

BPDS-32114-0809/22

8.5 FR

9 / 11 cm

220 cm

BPDS-32114-0811/22

8.5 FR

11 / 13 cm

220 cm

BPDS-32114-1005/22

10 FR

5 / 7 cm

220 cm

BPDS-32114-1007/22

10 FR

7 / 9 cm

220 cm

BPDS-32114-1009/22

10 FR

9 / 11 cm

220 cm

BPDS-32114-1011/22

10 FR

11 / 13 cm

220 cm

  • Home
  • Product Categories
  • Photo Gallery
  • About
  • Contact Us
Copyright © 2022 All Rights Reserved.
Business Cast by Axle Themes